Sika AnchorFix 3030 is an epoxy resin based, 2-part, thixotropic, high performance anchoring adhesive for anchoring threaded rods and reinforcing bars in both cracked and un-cracked concrete dry or damp concrete.
USAGE
Anchoring adhesive for fixing of non-expanding anchors in the following:
Structural work
- Rebar / steel reinforcement anchoring in new and refurbishment works
- Threaded rods
- Bolts and special fastening / fixing systems
Metalwork, carpentry
- Handrails, balustrades and supports
- Railings
- Window and door frames
Substrates
- Concrete (cracked and un-cracked)
- Hollow and solid masonry
- Wood
- Natural and reconstituted stone
- Solid rock
ADVANTAGES
- Long open Time
- Can be used in damp concrete
- High load capacity
- ETA for anchoring in cracked concrete
- ETA for post installed rebar connections
- Seismic tested (C1 & C2)
- Suitable for contact with drinking water
- Fire resistant
- Styrene-free
- Good adhesion to substrate
- Shrinkage-free hardening
- Low emissions
- Low wastage
COLOUR
Part A: OffWhite, Part B: Grey, Part A+B Mixed: Light Grey
PRODUCT INFORMATION
SHELF LIFE :24 months from date of production
STORAGE : The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +10 °C and +25 °C.
DENSITY: ~1.5 kg/l
MIX RATIO: Part A : Part B = 3 : 1 by volume
SUBSTRATE TEMP: +5 °C min. / +40 °C max.
Download datasheet for full information.
APPLICATION STEPS
SUBSTRATE QUALITY
Mortar and concrete must be at the required design strength. Substrate tensile / compressive strengths (concrete, masonry, natural stone) must be confirmed by testing. The anchor hole must always be clean, dry, free from oil and grease etc. Loose particles must be removed from the holes. Threaded rods and rebar’s must be cleaned thoroughly and free from dirt, oil, grease, corrosion products or any other substances and particles which could affect adhesion.
MIXING
preparaing cartridge 300ml
- Unscrew and remove the cap
- Cut the end off the protective film
- Screw on the static mixer
- Place the cartridge into the application gun ready for use
preparing cartridge 385 & 585 ml
- Unscrew the cap
- Remove the cap
- Screw on the static mixer
- Place the cartridge into the application gun ready for use
- When the work is interrupted the static mixer nozzle can remain on the cartridge after the gun pressure has been released. If the resin has hardened in the nozzle when work is resumed, a new nozzle must be attached.
CLEANING OF EQUIPMENT
Clean all tools and application equipment with Sika Colma Cleaner immediately after use. Hardened material can only be removed mechanically.